| Ideal Ground Resistance Meters |
| Ground Resistance Clamp Meter |
Simple-clamp-on operation ground leakage current,
audible resistance indication, open jaw indication, data hold, calibration loop included,
protective case included |
| MEGGER® 3-Pole Earth Resistance Meter |
2- & 3-point fall of potential methods, easy single
push-button operation, includes terminal shorting bars, rugged weatherproof case |
| MEGGER® 4-Pole Earth Resistance Meter |
3- & 4-point fall of potential methods, soil
resistivity, easy single push-button operation, includes terminal shorting bars, rugged
weatherproof case |
|
| Ideal Insulation Testers |
| MEGGER® Digital Insulation Tester |
250/500/1000V test voltages, test inhibition >25V,
default voltmeter to 600V AC/DC, digital display with analog arc, auto discharge, auto power off,
auto ranging, protective rubber boot, continuity, low battery indication, Cat III-300V, includes
carrying case
|
| MEGGER® 5kV Insulation Tester |
500/1000/2500/5000V test voltages, hand-crank or
battery operation, auto AC/DC to 600V, test, Cat III-300V, includes case |
| MEGGER® Hand-Crank Insulation Tester |
500V test voltage, handcrank operation, compact and
lightweight, includes carrying case |
|
| Ideal
800 Series Power Analyzer |
| Power Quality Analyzers |
Single- or three-phase measurements, True RMS, Data
logging (1 MB memory), Auto ranging, Min/max/avg, Energy and Harmonics Program, PowerVision®
Software, (Optional programs: Disturbances, Check-Meter, Fast-Check), Lightweight, portable design,
Easy-to-use push-button operation, Password protected on-screen setup, 160 x 160 pixel LCD, RS-232
interface, Customized data collection, Real-time clock, Programmable trigger-points and start/stop
time, Lifetime limited warranty. Power Measurements: Kilowatts, Voltamperes, Inductive reactive
power, Capacitive reactive power, Power factor, Frequency, Kilowatt hours, Reactive power per hour.
Harmonics Measurements: Total harmonic distortion, Harmonic factorization to 51st
harmonic |
|
| Ideal SureTest® Analyzers |
| SureTest® Circuit Analyzers |
True RMS, Measures voltage drop under 12, 15 and 20-amp
load, Line voltage, Peak voltage, Frequency, Ground-neutral voltage, Ground impedance, Hot and
neutral conductor impedances, Identifies proper wiring in 3-wire receptacles, Identifies false
(bootleg) grounds, Tests GFCls for proper operation, Verifies isolated grounds |
| SureTest® Circuit/Harmonics Analyzers |
Measures voltage drop under 15 and 20-amp load,
Harmonic distortion (%THD to 17th harmonic), Current measurements with clamp adapter, Event
recording, Line voltage, Peak voltage, Frequency, Ground-neutral voltage, Ground impedance, Hot and
neutral conductor impedances, Identifies proper wiring in 3-wire receptacles, Identifies false
(bootleg) grounds, Verifies isolated grounds, Tests GFCls for proper operation |
|
| Ideal Circuit Identifiers & Receptacle Testers |
| Circuit Identifiers |
Microprocessor controlled sensitivity level, Positively
identifies circuit breakers and fuses without service interruption, GFI tester checks proper wiring
sequence and GFI operation, Hand-held receiver, Visual and audible indicators, Impact-resistant
plastic construction |
| Circuit & Receptacle Testers |
Tests GFCI receptacles for proper operation, Tests for
correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and
ground reversed with open hot and ground fault interruption in 3-wire, 125VAC circuits,No-slip
ergonomic design maximizes comfort,Premium neon lamps prevent false readings,Tough,
impact-resistant case |
|
| Ideal Voltage & Continuity Testers |
| Vol-Con® Elite Voltage/Continuity Testers |
Digital circuitry for better resolution, Tests for AC
voltage from 24-600VAC, Tests for DC voltage from 6-220VAC, Audible continuity, Non-contact voltage
indication (40-600VAC), Replaceable silicone test leads, Low impedance to eliminate ghost voltages,
Integral lead storage |
| Vol-Con® XL & Vol-Test® XL |
Extremely rugged and reliable tester, Vibrates when
voltage is present, Tests AC/DC voltage, Replaceable leads with shielded probe tips, Bright,
long-life LEDs and neon indicator, Dual voltage indication for backup safety, Compact
size |
| Voltage Tester |
Extremely rugged and reliable, Vibrates when voltage is
present, Tests ACI/DC voltage from 80-600V, Independent circuitry provides a built-in backup safety
system, Replaceable leads with shielded probe tips, Bright long-life LEDs and neon indicator lamp,
Dual voltage indication for backup safety |
| Vol-Con® Voltage/Continuity Tester |
Extremely rugged and reliable three-in-one tester,
Vibrates when voltage is present, Tests for AC/DC voltage from 5-600V, Independent circuitry
provides a built-in backup safety system, Automatic switching continuity tester, Replaceable leads
with shielded probe tips, Bright, long life LEDs and neon indicator lamp, Dual voltage indication
for backup safety |
|
| Ideal Split-Jaw Electrical Tester & Non-Contact Voltage
Testers |
| Split-Jaw® Electrical Tester |
Split-Jaw current measurements, 200AAC current
capability, Audible continuity, Data hold, Auto power off, Replaceable test leads, Integral lead
storage, Low battery indication, Jaw opening is 1" (up to 1/0 copper cable) |
| Non-Contact Voltage Testers |
Tests for voltage from 40V to 600V AC, Audible and
visual indication, Locates breaks along live insulated wires, Tests for energized
circuits |
|
| Ideal Wire Sorter & Phase Rotation Testers |
| 3-Phase/Motor Rotation Tester |
Identifies three-phase sequence, Indicates motor
rotation, Checks for open phases, For use up to 600V, Meets IEC-1010 (EN61010) safety
requirements |
| Phase Rotation Tester |
For use up to 600V, Broad operating range, Color-coded
insulators over alligator clips, Shock resistant housing, No exposed metal parts,
Easy-to-read |
|
| Ideal Circuit, Twin Lead & Continuity Testers |
| Test-Glo® Circuit Tester |
Industrial-quality tester designed for safe, easy
checking of electrical circuits, spark-plugs, motors, fuses, etc., For use with 80V to 600VAC/DC,
Neon test lamp at front of probe, Resistors reduce voltage reaching leads, Long, thin handles with
no-slip safety rings, 24-in. lead (rated 10,000V) permits wide-span usage |
| Continuity Tester |
Pocket-size tester for use on electrical control
equipment and panel-board wiring, Checks continuity of dead circuits and grounds on conduit
systems, and identifies wires in multi-wire cables, Light signal indicates completed circuit,
Pocket clip reverses to function as probe, Bulb-in end of tester serves as flashlight, Removable
4-ft. test lead with alligator clip |
| Twin Lead Tester |
Checks voltage from 80V to 500VAC/DC, Heavy-duty test
probes |
|
| Ideal Infrared Thermometer, Light Meter |
| Infrared Thermometer |
15:1 angle of viewability, Built-in laser pointer,
Backlit display, Auto power off, Measures temperatures from 0°F to 500°F (-18°C to
260°C) |
| Digital Light Meter |
Wide lighting range, Foot candle and lux measurement,
Remote light sensor, Cosine and color corrected, Peak hold, Digital and analog output, Compact and
lightweight, Low battery indicator |
|