| SPECIFICATIONS: |
| Sensing element: |
Positive Ion Emission Heated Diode |
| Sensitivity: |
Moving probe per SAE Std. J1627 |
| Alarm sensitivity: |
| SW Position |
R134a |
R12 |
| Small |
0.5 oz./yr. |
0.1 oz./yr. |
| Medium |
1.0 oz./yr. |
0.5 oz./yr. |
| Large |
5.0 oz./yr. |
3.0 oz./yr. |
|
| Power: |
12VDC - internal rechargeable battery 12VDC - external battery using clamp/lighter plug 120VAC - wall adapter to charge battery |
| Warm up time: |
Approximately 2 minutes |
| Accuracy: |
Exceeds SAE J1627 |
| Probe length: |
4.5 feet |
| Ambient operating temperature: |
32° to 104° F |
| Dimensions / Weight: |
5.5" x 10.5" x 8.5" / 5 Ibs |
| Agency listings: |
UL file SA9717, SAE J1627, CE-mark |
| Leak alarm: |
Audible Alarm and Visible Neon Lamp |
| Response time: |
Approximately 1 second |